SpletTracStar LDP Intracranial Access Catheter - TRX Tip - 6Fr x 95cm $750.00. Bard. Model #: MSXL17110 MicroSheath XL Straight Peripheral Support Catheter - 7Fr x 110cm $75.00. Add to Cart The item has been added. Merit Medical. Model #: PV512538U2 Performa Angiographic Catheter - Transradial Peripheral - ULTIMATE 2 - 5Fr x .038" x 125cm ... SpletDevice Classification Name. catheter, percutaneous, neurovasculature. 22. 510 (k) Number. K203764. Device Name. TracStar Large Distal Platform, ZOOM 88 Large Distal Platform, ZOOM 88-T Large Distal Platform. Applicant. Imperative Care Inc.
Tracstar guide catheter
Did you know?
Splet14. nov. 2014 · 1178 Views Download Presentation. GUIDING CATHETERS. Dr Bijilesh Uppalakal. Functions of a Guide Catheter. Support for device advancement Conduit for device and wire transport Vehicle for contrast injection Measurement of Pressure Different makes, shapes, sizes & uses. Diagnostic vs Guide catheters. Stiffer shaft. SpletComparative study of intracranial access in thrombectomy using next generation 0.088 inch guide catheter technology Devin V. Bageac, Blake S. Gershon, Jan Vargas, Maxim Mokin, Zeguang Ren, Deeksha Chada, Aquilla S. Turk, M. Imran Chaudry, Raymond D. Turner, Johanna T. Fifi , Tomoyoshi Shigematsu , Reade De Leacy
SpletThe objective of this study is to evaluate the safety of stroke thrombectomy using a novel 0.088 inch guide catheter designed for intracranial navigation. Methods This is a … SpletTracStar LDP was exchanged for an alternative guide catheter in one case due to catheter kinking, and in two cases due to lack of support. Conclusion Use of Tracstar LDP during flow-diversion and sent-assisted coiling of cerebral aneurysms is safe and effective.
Splet01. avg. 2024 · A novel device -the TracStar Large Distal Platform (LDP) -may offer improved navigation of tortuous vasculature as well as more distal final positioning when compared to commonly used guide catheters. SpletClinical Evidence. Imperative Care is dedicated to the continued generation of robust clinical research evidence in support of better care for stroke patients. We believe that the current evidence, as well as the anticipated future studies we are planning, will assist physicians in selecting the most appropriate treatment for their patients.
Splet17. nov. 2024 · Results The TracStar LDP guide catheter was successfully used in 107 mechanical thrombectomies. In anterior circulation ELVO, the guide catheter advanced into the cavernous segment of the internal ...
SpletThe TracStar LDP was used in 77% (10/13) of patients; the Zoom 88 guide catheter was used in 23% (3/13) of patients. The type of intervention was acute ischemic stroke in 69% (9/13) of patients and aneurysm embolization in 31% (4/13) of patients. healthgrades hospital searchSplet31. maj 2024 · The TracStar LDP large bore guide catheter is safe and effective at navigating the tortuous vascular anatomy often encountered during mechanical … good advice for college studentsSpletResults Over the 14-month study period, 127 femoral access cases were identified where the TracStar LDP guide catheter was utilized for aneurysm treatment (80% of cases, 102/127 ), intracranial angioplasty/stenting (13% of cases, 17/127), venous sinus stenting (3% of cases, 4/127), and other pathologies (3% of cases, 4/127). All cases utilized a … healthgrades john c herzogSpletVascular guide-catheter, single-use. A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional … healthgrades jim tonerSplet26. mar. 2016 · Guide catheter construction differs between manufacturers and usually are very different from their diagnostic counterparts. A stiffer shaft, thinner walls, larger internal lumen diameter, a shorter and more angulated tip (110° vs. 90°), and a reinforced construction (3 vs. 2 layers) are some of the characteristics that differentiate guide … healthgrades orthopedic doctorsSpletGuiding catheter system offered with inner select catheters with a hydrophilic coating for navigation and vessel selection: 5/6: 95: 0.059/0.071: Yes: Chaperon catheter, no; inner select catheter, yes healthgrades hospital awardsSpletCatheter, Percutaneous DQY 21 CFR. 870.1250 Imperative Care Inc. K180169 D. Device Description: The Imperative Care Large Distal Platform (LDP) Catheters include the … healthgrades mercury crm